NIOSH ratings

rating system for respirators designed to protect against contaminated air particles
(Redirected from NIOSH air filtration rating)

The NIOSH ratings are a set of rules that NIOSH uses to check respirators. Today, the rules NIOSH uses is called 42 CFR 84. NIOSH uses these rules to check N95 respirators. Before the N95, other rules have been used in the past, like 30 CFR 11. Also, some less-seen respirators can have filters that can be changed. These respirators are called elastomeric respirators. See the last chart for other less-seen respirators. NIOSH checks all these less-seen respirators too.[1]

NIOSH ratings
An elastomeric respirator with changeable filters. What is less known is that they can have N95 filters too.
Other name(s)NIOSH ratings
Regulated byNational Institute for Occupational Safety and Health
Regulation30 CFR 11, 42 CFR 84, ANSI Z88.7-2001

Under 42 CFR 84, rules for chemical filters are also made by the American National Standards Institute. One rule is called ANSI K13.1-1973, which are rules for chemical cartridge colors.[2] A new set of rules under ANSI K13.1-1973 is called ANSI Z88.7-2001.[3] To stay simple, ANSI's color rules are not listed below.

Old ratings

change

Bureau of Mines

change
 
Hawks Nest Tunnel Disaster memorial

The first respirator rating rules were made due to miners dying. By 1907, 3,243 miners had died. The United States Bureau of Mines (USBM) was made to give out information for miners and mine owners, so fewer miners would die. Some respirator rules were made, but few wanted rules that had to be followed.[4]

Then, in 1929, the Hawks Nest Tunnel Disaster happened. The number of dead was so great from the breathing of silica (silicosis), that the USBM had to make respirator rules that people had to follow. The rules at the time checked respirators with dust that made people sick. Each dust rule is checked by itself before being passing the check. They were:[5]

  • Type A - Dust
  • Type B - Fume - tested with lead fume
  • Type C - Mist

Soon, "Type A/B/C" was seen less over time. People often said 'Dust/Fume/Mist' in place of 'Type A/B/C'. And often, respirators passed most of the 'Dust', 'Fume', and 'Mist' rules.[5]

"Dust/Mist" referred to the same test dust: silica.[5] See the chart below for the rules.

MSHA/NIOSH - 30 CFR 11

change
 
MSHA-NIOSH approval Label, 30 CFR Part 11. It is not used today.
 
3M 6200 with magenta 'Dust-Fume-Mist Radionuclides Asbestos' (30 CFR HEPA) words on the magenta part.
 
This is another HEPA respirator with MSHA/NIOSH logos.

The Federal Coal Mine Health and Safety Act made the Mine Safety and Health Administration (MSHA). At the same time, the Occupational Safety and Health Act of 1970 made NIOSH. Soon, both US government agencies checked that respirators followed rules under '30 CFR Part 11'.[5] 30 CFR 11 rules include a MSHA-NIOSH approval label, which can be seen in the picture.

30 CFR 11 rules were the same as USBM rules. But, the 30 CFR 11 rules added HEPA rules for respirators. The most used rules are below:

(NOT USED) 30 CFR 11 ratings
Dust used with rule Respirator

rule or 'approval'

Dust pass from filter,

to the mouth and nose, by rule

Percentage of dust not passed

to the mouth and nose

158.4 milligram (mg) silica Use-one-time 'Dust/Mist' respirators 1.8 mg 98.86%
158.4 mg, most likely silica Respirators with 'Dust/Mist' filters that can be changed 1.5 mg 99.05%
0.3 micron Dioctyl phthalate HEPA (most likely also follows 'Dust/Mist' rule or approval) No information 99.97%

Some abbreviations of these respirators include: 'DM' and 'DFM',[6] which are 'Dust/Mist' and 'Dust/Fume/Mist' ('Fume' is not in the chart above).

Ratings today, under 42 CFR 84

change
 
Today's NIOSH approval label, 42 CFR 84. This is not the same as the 30 CFR 11 label.
 
This elastomeric respirator has P100 filters. P100 filters can be magenta in color.
 
This N95 is also a Part 84 respirator.

In 1995, NIOSH made new respirator rules.[7] The rules are stored in 42 CFR 84 in the Code of Federal Regulations (CFR). The CFR is part of the Federal Register.[2] HEPA, or 'HE', is now only used for powered air-purifying respirators. In 2020, new ratings were added for these respirators. They were PAPR100-N and PAPR100-P.[8] HEPA for other respirators is now 'P100'. P100 is the only type of filter or respirator that can have the color magenta. Also, the NIOSH approval label for 42 CFR 84 is not the same as the label for 30 CFR 11.

Under the new rules, MSHA stopped checking respirators.[7] Also, in the United States, it is against the rule of law to sell things that are not respirators with these rules or ratings. Respirators that are not checked by NIOSH should also not be sold.[9]

Under 42 CFR 84, respirators should be tested with salt dust if the rating starts or ends with the letter 'N'. The amount of salt dust is 200 milligrams (mg). Dioctyl phthalate is used if the rating starts or ends with the letter 'R' or 'P'. 'R' and 'P' mean the respirator or 'filter' is made to stop oil mist. For 'R', the amount of DOP mist used is 200 mg. For 'P', the amount of DOP mist used does not have a number. It does not stop for a long time.[10] All the new ratings are below:

NIOSH ratings, 42 CFR 84, used today
Dust used with rule Respirator

rule or rating

Percentage of dust not passed

to the mouth and nose

NaCl (N) or DOP (R,P) N95, R95, P95 95%
N99, R99, P99 99%
N100, R100, P100 99.97%
HE, PAPR100-N, PAPR100-P

If the rating ends in 100, the respirator or filter can stop asbestos.[11]

Last chart: Type of respirator by TC number

change

This chart shows which less-seen respirator each TC number goes to. This can be used to check if a respirator is real in the NIOSH CEL.

Approval schedules[12][13]
US Code Gas mask Air-line SCBA Particulate PAPR Chemical

Cartridge

Bureau of Mines (shown on the respirator as 'BM') BM-14 BM-19 BM-13 BM-21 N/A BM-23
30 CFR 11 TC-14G TC-19C TC-13F TC-21C TC-21C TC-23C
42 CFR 84 (used today) TC-14G TC-19C TC-13F TC-84A TC-21C TC-23C

N95s use the TC number 'TC-84A'.

Other websites

change

References

change
  1. "42 CFR Part 84 Respiratory Protective Devices". The National Personal Protective Technology Laboratory. National Institute for Occupational Safety and Health. 4 March 1997. Retrieved 8 June 2023 – via U.S. Centers for Disease Control and Prevention.
  2. 2.0 2.1 https://www.ecfr.gov/current/title-42/chapter-I/subchapter-G/part-84
  3. American National Standard for Color-Coding of Air Purifying Respirator Canisters, Cartridges, and Filters (PDF), American Industrial Hygiene Association, ANSI, 2001-05-03
  4. Howard W., Spencer. "The Historic and Cultural Importance of the HAWKS NEST TUNNEL DISASTER" (PDF). American Society of Safety Professionals.
  5. 5.0 5.1 5.2 5.3 Spelce, David; Rehak, Timothy R; Meltzer, Richard W; Johnson, James S (2019). "History of U.S. Respirator Approval (Continued) Particulate Respirators". J Int Soc Respir Prot. 36 (2): 37–55. PMC 7307331. PMID 32572305.
  6. NIOSH Recommended Guidelines for Personal Respiratory Protection of Workers in Health-care Facilities Potentially Exposed to Tuberculosis. 1992.
  7. 7.0 7.1 "DEPARTMENT OF HEALTH AND HUMAN SERVICES Public Health Service 42 CFR Part 84" (PDF). US Federal Register. pp. 26850-26893. Retrieved 2024-05-08.
  8. "Approval Tests and Standards for Air-Purifying Particulate Respirators". 2020-04-14.
  9. "Counterfeit Respirators / Misrepresentation of NIOSH Approval". May 23, 2024.
  10. "DHHS Pub 96-101 NIOSH Guide to the Selection & Use of Particulate Respirators Certified Under 42 CFR 84". NIOSH.
  11. "NIOSH Pocket Guide - Asbestos". CDC.
  12. "ndustrial Hygiene Field Operations Manual Technical Manual NMCPHC-TM6290.91-2 10 MAY 2021" (PDF).
  13. "NIOSH Guide to the Selection and Use of Particulate Respirators". CDC NIOSH. January 1996.
change