Metre Convention

1875 international treaty

The Metre Convention is the treaty that set up the International Bureau of Weights and Measures (BIPM). The BIPM is an inter-governmental organization that is responsible for harmonizing systems of measurement across the world. The treaty was first made in 1875 between 17 countries.

Metre Convention signatories:
  Member States
  Associate Member States

The member countries agreed to share the costs of running a laboratory on neutral territory. The international prototype metre and the international prototype kilogram would be kept at the laboratory. Member state's national prototype metres and kilograms would be compared with the international prototypes at regular intervals. Member states would have regular meetings to discuss developments in measurement technology.

In 1921 the treaty was extended to cover electrical and all other physical measurements. This enabled the BIPM to published the standards for the International System of Units (SI). Under SI, units of measurements that are used in science and engineering were defined in a logical manner. The rules for SI also standardized the way in which physical quantities are written.

In 2014 the BIPM had 55 member countries.

Before the treaty

change

The metric system was developed in France in the 1790s. The length of the metre was made to be one ten millionth of the distance between the North Pole and the equator. Between 1791 and 1798 the French men Delambre (a mathematician and astronomer) and Méchain (an astronomer) measured the distance between Dunkirk and Barcelona. The measurements were used to make a metal bar exactly 443.296 lignes long (the ligne is an old French unit of length equal to one twelfth of a French inch). The bar would be used as a standard for the metre. The bar was later called the metre des archives. By the 1860s it was found that the metre des archives was 0.03% shorter than it was supposed to have been.[1]

The Great Exhibition in London in 1851 and the Paris International Exhibition in 1867 had shown the need for different nations to use the same units of measurement.[2] In the 1860s there were many discussions by astronomers and surveyors from outside France whether they should use the metre des archives or whether they should use a "new metre" that took account of the 0.03% error. Prussia took the lead in organizing conferences in Berlin to discuss the matter. France did not take part in the conferences. Before any actions could be taken the Franco-Prussian War broke out. Prussia defeated France and the German Empire was formed.[1]

In 1875 France invited representatives to Paris to discuss the matter. This helped France to score a diplomatic victory over Prussia and the German Empire.[1]

Treaty details

change

The treaty was signed by seventeen of the countries at the conference in Paris on 20 May 1875.[3] The United Kingdom and the Netherlands went to the conference but did not sign the treaty at that time. After further consideration, the United Kingdom did sign the treaty in 1884.[4]: 75–76 

The meeting agreed:

  • Three organisations would be set up to administer the treaty.
  • Identical copies of the metre and kilogram would be manufactured. One copy of each would be chosen as the international master copy. Other copies would be distributed to member states.
  • The master copy of the metre and the kilogram would be kept in the laboratory.
  • The laboratory would be on neutral territory.
  • Members would compare their copies with the master copies at regular intervals.
  • The organisations would promote the use of the metric system.

International Bureau of Weights and Measures (BIPM)

change

The organization set up by the treaty was the International Bureau of Weights and Measures. Its French name is Bureau international des poids et mesures. Its abbreviation is BIPM. The BIPM has its headquarters at the Pavillon de Breteuil, Sèvres, France (close to Paris). About 70 people work at the BIPM. The budget for 2013 was over €10 million ($12 million).[5]

The three organisations were set up under the treaty. They are:[6]

The Bureau has responsibility for safeguarding the international prototype kilogram.

The official language for the organisations is French. Until 1988 all reports of meetings were only published in French. Since then both English and French have been used. Abbreviations are based on the French words, not English words.[1]: xx  Official communications between the BIPM and France are conducted via the French Foreign Ministry. Official communications with other countries are conducted via that country's embassy in Paris.

General Conference on Weights and Measures (CGPM)

change

The General Conference on Weights and Measures was set up under the Metre Convention as an organ of the BIPM. It gives the BIPM its mandate and budget on behalf of the member states. Its French name is Conférence générale des poids et mesures. Its abbreviation is "CGPM".

The CGPM meets every four to six years. The first meeting was in 1889 and the 24th meeting was in 2011.[7] Each member state has one vote. France is represented by its foreign minister and by the president of the French Academy. The French Foreign minister is the chairman of the opening and closing sessions of any CGPM session. The president of the French Academy is the chairman of other meetings of the CGPM.

The CGPM:

  • Agrees the BIPM budget.
  • Agrees member states' payments.
  • Appoints members to the CIPM.
  • Accepts proposals from the CIPM.

International Committee for Weights and Measures (CIPM)

change

The International Committee for Weights and Measures was set up under the Metre Convention as an organ of the BIPM. It advises the CGPM and supervise the BIPM. Its French name is Comité international des poids et mesures. Its abbreviation is CIPM.

The CGPM has 18 members. These members are well-known measurement experts who are elected by the CGPM. They must all come from different countries. One of the CIPM members must be French. They meet once or twice a year in Paris. The CIPM is assisted by a number of Consultative Committees. In February 2014 there were ten such committees. Nine of the committees are dedicated to special types of measurement such as Electricity and Magnetism, Length, Photometry and Radiometry, Thermometry and Time and Frequency. The CIPM appoints people to these committees.[8]

The tenth committee is called the Consultative Committee for Units (CCU). Its chairman is appointed by the CIPM. Other members of the committee are appointed by other organizations. These organizations include International Organization for Standardization (ISO) and National Institute of Standards and Technology (NIST). The CCU's task is to ensure that all the definitions of SI are consistent. It also drafts the SI standard which is called the SI Brochure.[8][9]

Pavillon de Breteuil

change

The BIPM's offices and laboratories art at the Pavillon de Breteuil, Sèvres, France (close to Paris).

The BIPM looks after the International Prototype Kilogram (IPK) for the CGPM. It provides laboratory services for the CGPM and CIPM. Member states use the BIPM laboratories when they check their own copy of the kilogram against the IPK. The BIPM offices are also the headquarters for the CGPM and CIPM.

Activities

change

In 1875 the convention only dealt with standardization of the kilogram and the metre. The convention was revised in 1921 to accommodate all physical measurements. In 1933 the CGPM approved efforts that were being made to merge electrical and photometry units into the metric system.[10]

Development of SI

change

During the late nineteenth and early twentieth century many new units of measure were defined using the metric system. Units of measure used in electrostatic applications, electromagnetic applications and electrical distribution systems were incompatible with each other.[11] The use of standard gravity in force and pressure definitions resulted in more units of measure being defined than were necessary.

After the Second World War the International Union of Pure and Applied Physics (IUPAP) and the French Government asked the BIPM to look into the matter. In 1948, the 9th CGPM asked the CIPM to conduct a study into units of measurement used by member states.[12] The CIPM reported back and in 1954 the 10th CGPM decided to set up a new system of units. There would be six base units. These were the metre, kilogram, second, ampere, degree Kelvin (later renamed kelvin), and candela. The new system was published in 1960. The 11th CGPM named it the International System of Units. The short name was "SI". This came from the French name, Le Système international d'unités.[9]: 110 [13] The BIPM described SI as "the modern metric system".[9]: 95 

Since 1960 the BIPM has made several refinements to SI. Some of the refinements include developing new ways of making high precision measurement. Other refinements include small changes to details of definitions.

Coordinating time

change

The atomic clock has made very precise time-keeping possible. The earth is slowing down. A the "time of the dinosaurs" the earth rotated once every 23 hours.[14] It is now possible to measure variations in the Earth's rotation caused by volcanoes and tsunamis.[15] This is done by the International Earth Rotation Service (IERS). The IERS proposes leap seconds as and when these are needed. Under the Metre Convention, the BIPM has the task of coordinating over 200 atomic clocks around the world. These clocks are located in 50 different national laboratories.[16]

Mutual Recognition Agreement (MRA)

change

Many measuring devices need to be recalibrated at regular intervals. These devices might be petrol pumps. They might be weighing scales. They might be complex medical equipment like MRI scanners. A certificate is issued when the device is recalibrated. The device that is used to do the calibration must itself be calibrated. These devices are often recalibrated in a national metrology laboratory. Legal problems can arise if a calibration done in one country is not recognised in another country.

Membership

change

Some countries are full members of the CGPM and have a vote at CGPM meetings. These countries have their own copy of the prototype kilogram. They also take part in the CIPM MRA program.

Other countries are associate members. They take part on the CIPM MRA program. They may speak at CGPM meetings but not to vote at these meetings. They do not have their own copies of the prototype kilogram.

Members

change

Associate member states

change

At its 21st meeting (October 1999), the CGPM created the category of "associate" for those states not yet members of the BIPM and for economic unions.[18]

International Organisations

change

The following international organisations have signed the CIPM MRA:

Former member states

change

  Cameroon (1970–2012)[19]
  North Korea (1982–2012)[20]
  Dominican Republic (1954-2014)[21]
  Yemen (2014-2018)[21]

  1. 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 Signed the original agreement in 1875. Country ratified agreement in the year given in brackets
  2. Austria-Hungary until 1919
  3. Original signatory in 1875. Membership lapsed 1881
  4. 4.0 4.1 Czechoslovakia until 1992
  5. German Empire until 1919
  6. Irish Free State until 1937
  7. 7.0 7.1 Sweden and Norway until 1905
  8. Russian Empire until 1917
  9. Federal Republic of Yugoslavia until 2006
  10. Ottoman Empire until 1919
  11. Original signatory in 1875. Membership lapsed 1957.

References

change

Official texts

change

Citations

change
  1. 1.0 1.1 1.2 1.3 Quinn, Terry (2012). From artefacts to atoms: the BIPM and the search for the ultimate measurement standards. New York: Oxford University Press. ISBN 978-0-19-530786-3.
  2. Basil Swindells, National Physical Laboratory, Teddington (1975), "Centenary of the Convention of the Metre", Platinum Metals Review, vol. 19, no. 3, Johnson Matthey Plc{{citation}}: CS1 maint: multiple names: authors list (link)
  3. "Message from the President of the United States, transmitting a report of a metric convention between the United States and certain foreign governments, signed at Paris on the 20th of May, 1875". 10 March 1876. Archived from the original on 1 March 2005. Retrieved 25 February 2014. {{cite journal}}: Cite journal requires |journal= (help)
  4. Hallock, William; Wade, Herbert T (1906). "Outlines of the evolution of weights and measures and the metric system". London: The Macmillan Company.
  5. "The BIPM headquarters". International Bureau of Weights and Measures. Retrieved 15 February 2014.
  6. "Bureau international des poids et mesures - International Bureau of Weights and Measures - (BIPM)" (PDF). International Bureau of Weights and Measures. Archived from the original (PDF) on 27 February 2005. Retrieved 23 February 2014.
  7. "General Conference on Weights and Measures". International Bureau of Weights and Measures. Archived from the original on 26 September 2012. Retrieved 23 February 2014.
  8. 8.0 8.1 "Criteria for membership of a Consultative Committee". Bureau International des Poids et Mesures. Archived from the original on 17 April 2012. Retrieved 25 September 2012.
  9. 9.0 9.1 9.2 International Bureau of Weights and Measures (2006), The International System of Units (SI) (PDF) (8th ed.), ISBN 92-822-2213-6
  10. "Resolutions of the CGPM: 8th meeting (3-10 October 1933)". International Bureau of Weights and Measures. Retrieved 1 March 2014.
  11. Fenna, Donald (2002). Weights, Measures and Units. Oxford University Press. International unit. ISBN 0-19-860522-6.
  12. 9th CGPM (1948): Resolution 6
  13. 11th CGPM (1960): Resolution 12
  14. "NASA Explains Why Clocks Will Get an Extra Second on June 30". NASA. 29 June 2012. Archived from the original on 28 May 2014. Retrieved 8 March 2014.
  15. "NASA Details Earthquake Effects on the Earth". Jet Propulsion Laboratory, California Institute of Technology. 10 January 2005. Retrieved 28 February 2014.
  16. "International Atomic Time". Bureau International des Poids et Mesures. Retrieved 28 February 2014.
  17. 17.0 17.1 "Members of the International Committee for Weights and Measures (CIPM) 1875-1977" (PDF). BIPM. October 2013. Retrieved 12 March 2014.
  18. BIPM official site:Procedure for a State or Economy to become an Associate of the General Conference Archived 2014-07-03 at the Wayback Machine
  19. International Bureau of Weights and Measures official site: The Republic of Cameroon, retrieved 4 August 2013
  20. International Bureau of Weights and Measures official site: The Democratic People's Republic of Korea Archived 2013-10-29 at the Wayback Machine, retrieved 4 August 2013
  21. 21.0 21.1 "BIPM – Dominican Republic [Member State]". www.bipm.org. Retrieved 29 March 2017.